Type VKP-KLT04 is available for on-site testing lamps, which are used on public lighting system. The handle of meter is fast and easy with shoulder bag, device weight 2kg.
Output voltage
230 V/ 50 Hz
Power
max.100 VA (higher as required)
Battery
4x3,6 V Li.Ion /3,3Ah
Stored energy
kb. 40 Wh
Max. output current
0,5 A (AC)
Operating time
50 VA continuous load ca. 30 min.; 1 hour with discontinuous load
Protection
Short circuiting, overload current and overvoltage protection